Electric Strikes vs. Magnetic Locks: Complete Buyer’s Guide for Commercial Doors (2026)

Published by BandHdepot.com — Your trusted wholesale source for commercial electric strikes, magnetic locks, and access control hardware from HES, Securitron, SDC, RCI, Schlage, and Von Duprin.

What You’ll Learn: This guide breaks down the key differences between electric strikes and magnetic locks (maglocks) for commercial access control. We cover how each device works, fail-safe vs. fail-secure operation, holding force, power requirements, fire and life safety code compliance, installation considerations, and which lock type is best for your specific application. Whether you’re a locksmith, facility manager, contractor, or architect, this guide will help you specify the right electrified lock for every door.

1. How Electric Strikes and Magnetic Locks Work

Electric Strikes

An electric strike replaces the standard strike plate in the door frame. The door still uses a conventional mechanical lockset with a latchbolt or deadlatch. When the access control system sends a signal, the strike’s keeper pivots open, allowing the latch to pass through without retracting — the door opens even though the lock itself is still “locked.” Once the door closes, the keeper snaps back and the latch engages the strike again automatically.

Because the mechanical lock stays on the door, an electric strike is essentially an add-on that electrifies an existing opening. The lock still accepts a key, so occupants or security staff have a mechanical override available at all times.

Magnetic Locks (Maglocks)

A magnetic lock uses an electromagnet mounted on the door frame header and a steel armature plate mounted on the door. When energized, the electromagnet bonds to the armature plate and holds the door closed through pure magnetic force. There is no latchbolt, no deadbolt, and no mechanical locking mechanism — the door is held shut entirely by electricity.

When the access control system signals the maglock to release, power is cut and the magnetic bond breaks instantly, allowing the door to swing open. The moment the door closes and power is restored, the magnet engages the armature plate and locks the door again.

2. Side-by-Side Comparison: Electric Strike vs. Magnetic Lock

Feature Electric Strike Magnetic Lock (Maglock)
Locking Mechanism Mechanical latch released electrically Electromagnetic bond — no mechanical parts
Mounting Location Inside door frame (replaces strike plate) Surface-mounted on frame header and door
Fail Mode Fail-safe or fail-secure (configurable) Fail-safe only (unlocks on power loss)
Power Draw Momentary (100–300 mA only during unlock) Continuous (250–500 mA while locked)
Voltage 12 or 24 VDC (some models 12 VAC) 12 or 24 VDC
Typical Holding Force Dependent on mechanical lock (effectively 1,200–1,500 lb with Grade 1 lockset) 600–1,200 lb (surface-mount); 300–600 lb (concealed)
Key Override Yes — mechanical key backup always available No — power-dependent only
Lifecycle 5,000–50,000 cycles (mechanical parts) 100,000+ cycles (no moving parts)
Fire/Egress Compliance Straightforward — lever latch allows free egress from inside Requires REX sensor, emergency release, and fire alarm tie-in
Installation Difficulty Medium-High (frame modification required) Low (surface-mount; minimal frame work)
Appearance Concealed inside frame — clean look Visible on frame header and door face
Best For Perimeter doors, code-regulated entries, retrofits Glass doors, interior controlled spaces, quick installs
Available at BHD ✓ In Stock ✓ In Stock

3. Fail-Safe vs. Fail-Secure: Why It Matters

Understanding fail modes is the single most important factor when choosing between an electric strike and a magnetic lock. The fail mode determines what happens to the door during a power outage, fire alarm, or system failure.

Fail-Safe (Unlocks on Power Loss)

The door unlocks when power is cut. This prioritizes life safety — occupants can always exit during an emergency, even if the electrical system fails.

Magnetic locks are always fail-safe. Since the magnet requires continuous power to hold the door, any interruption — power outage, fire alarm activation, or intentional cut — releases the door immediately.

Fail-Secure (Locks on Power Loss)

The door stays locked when power is cut. This prioritizes asset security — protected spaces remain secured even during power failures.

Electric strikes can be configured as fail-secure. Because the mechanical lock stays engaged independently of power, a fail-secure strike keeps the latch in the locked position during an outage. Free egress from the inside is maintained by the mechanical lever handle.

Why this matters for your project: If you need a door that stays locked during a power outage (server rooms, evidence storage, pharmacy vaults), you need a fail-secure electric strike. If the door must release for life safety during any emergency (main exits, fire stairwells), either a fail-safe electric strike or a magnetic lock will work — but the maglock will require additional code-compliance hardware (REX sensors and emergency release).

4. Holding Force and Security

Holding force measures how much pull is needed to force a locked door open. The right holding force depends on the door size, security level, and environmental conditions (wind load on exterior doors, for example).

Electric Strikes

An electric strike’s security depends on the mechanical lock installed on the door. The strike itself releases the keeper, but the latchbolt and lock body do the actual holding. A Grade 1 commercial mortise lock paired with an electric strike provides effective holding strength of 1,200–1,500 pounds or more. This makes electric strikes an excellent choice for high-security perimeter doors where both electronic access control and strong physical security are required.

Magnetic Locks

Standard surface-mount maglocks provide 600 to 1,200 pounds of holding force. The most common commercial models are rated at 600 lb (single door) or 1,200 lb (double magnet or high-security). Concealed maglocks, which mount inside the frame for a cleaner look, typically offer 300–600 lb of holding force.

For most standard commercial interior doors, 600 lb is sufficient. Exterior doors, high-wind locations, and high-security spaces typically call for 1,200 lb models. Secure rooms and sensitive areas may warrant 1,500 lb units or paired magnets.

Application Recommended Holding Force Suggested Lock Type
Interior office doors 600 lb Maglock or electric strike
Perimeter entry doors 1,200–1,500 lb Electric strike with Grade 1 lockset
Glass storefronts 600–1,200 lb Maglock (surface-mount)
Server rooms / data centers 1,200 lb+ Fail-secure electric strike
Exterior doors with wind load 1,200–1,500 lb Electric strike preferred
Interior controlled areas (labs, stockrooms) 600–1,200 lb Maglock or electric strike

5. Power Requirements and Wiring

Power consumption is a significant difference between these two lock types and directly affects your project’s power supply sizing, battery backup runtime, and long-term energy costs.

Electric Strike Power

Electric strikes draw power only during the moment of release. A typical commercial electric strike draws 100–300 mA at 12 or 24 VDC, but only for the few seconds the door is being unlocked. The rest of the time, a fail-secure strike draws zero power. This makes electric strikes extremely energy-efficient and allows a single power supply to serve multiple strikes on the same circuit.

Magnetic Lock Power

Maglocks draw power continuously — 250–500 mA at 12 or 24 VDC, 24 hours a day, 7 days a week. At 24 VDC and 250 mA, a single maglock consumes approximately 6 watts continuously. Over a year, that adds up. More importantly, continuous draw means your battery backup must be sized to keep the maglock energized during outages. Buildings with many maglocked doors often need larger UPS systems and more frequent battery replacements.

Wiring Guidelines

Specification Electric Strike Magnetic Lock
Operating Voltage 12/24 VDC (some 12 VAC) 12/24 VDC
Current Draw 100–300 mA (momentary) 250–500 mA (continuous)
Wire Gauge (runs under 100 ft) 18 AWG 18 AWG
Wire Gauge (longer runs) 16 AWG 16 AWG recommended
Battery Backup Impact Minimal — draws only during unlock events Significant — continuous draw depletes batteries faster

Pro tip: Always install a suppression diode across the maglock coil to protect the access control panel from voltage spikes when the magnet de-energizes. For strikes, verify whether the model requires DC or AC — wiring an AC strike on DC (or vice versa) will damage the solenoid.

6. Fire Code and Life Safety Compliance

Code compliance is where the choice between electric strikes and maglocks has the greatest practical impact. The governing codes include NFPA 101 (Life Safety Code), the International Building Code (IBC), and local amendments enforced by the Authority Having Jurisdiction (AHJ).

Key Principle: Egress doors must be readily openable from the egress side without a key, special knowledge, or effort. This is a fundamental requirement across all building codes (NFPA 101, IBC Chapter 10, and local fire codes). Both electric strikes and maglocks can meet this requirement — but the path to compliance differs significantly.

Electric Strikes and Code Compliance

Electric strikes generally have the simpler path to compliance. Because the door retains its mechanical lockset with a lever handle, occupants on the egress side can always exit by simply turning the lever — the mechanical latch retracts regardless of the strike’s electrical state. This satisfies the “no special knowledge or effort” requirement automatically.

Fail-secure electric strikes are code-compliant for most applications because the lever provides free egress even when the strike is locked. Fail-safe strikes comply by default since the door unlocks on power loss.

Magnetic Locks and Code Compliance

Magnetic locks require additional hardware and integration to meet egress codes. Since there is no mechanical latch or lever on a maglocked door, the magnet must release to allow exit. Code compliance for maglocks typically requires all of the following:

Important: Always verify maglock egress requirements with your local AHJ before installation. Requirements vary by jurisdiction, building type, and occupancy classification. The fire alarm integration requirement is standard across most commercial jurisdictions.

Referenced Codes and Standards

Code/Standard What It Governs
NFPA 101 — Life Safety Code Egress requirements, means of egress hardware, door locking arrangements on egress doors
IBC Chapter 10 — Means of Egress Door operations, locking arrangements, electrified hardware on egress doors
NFPA 72 — National Fire Alarm Code Fire alarm system integration requirements for access control release
NFPA 80 — Fire Doors and Other Opening Protectives Hardware requirements for fire-rated door assemblies (both strikes and maglocks)
Local AHJ Amendments Jurisdiction-specific requirements that may exceed NFPA/IBC minimums

7. Installation Comparison

Installing an Electric Strike

Electric strike installation requires modifying the door frame to accommodate the strike body. For hollow metal frames, this typically means cutting a larger prep in the frame jamb (or using the existing ANSI strike prep if the strike is designed for it). For wood frames, a mortise pocket is cut. The installer must route low-voltage wiring through the frame to the strike location.

Installation considerations:

Installing a Magnetic Lock

Maglock installation is simpler and faster. The electromagnet mounts to the frame header (top of the frame) with screws, and the armature plate mounts to the top edge of the door. No frame modification or mortising is needed.

Installation considerations:

Bottom line on installation: If speed and simplicity are priorities — especially on glass, aluminum, or frameless doors where frame modification is difficult — a maglock is the faster install. If the door already has a compatible mechanical lockset and you want a concealed, clean-looking solution, an electric strike is the better long-term choice despite the more involved installation.

8. Best Applications for Each Lock Type

Choose an Electric Strike When:

Choose a Magnetic Lock When:

9. Top Brands: Electric Strikes and Magnetic Locks

Electric Strike Brands

Brand Popular Series Known For
HES (Assa Abloy) 1006, 5000, 9600 Industry standard; widest compatibility with ANSI lock preps
SDC (Security Door Controls) 15, 45A, 55 Heavy-duty commercial; popular in institutional and government projects
RCI (Rutherford Controls) F2, 65 Series Versatile models for cylindrical and mortise locks
Folger Adam (HES) 300, 310 Legacy brand; heavy-duty detention and institutional applications
Trine 3000, 4100 Cost-effective commercial strikes; good for multi-unit projects

Magnetic Lock Brands

Brand Popular Series Known For
Securitron (Assa Abloy) M32, M62, M82 Industry leader; 600–1,200 lb models; built-in bond sensor available
SDC (Security Door Controls) 1511, 1571, 1581 Wide range of holding forces; EMLock series with integrated sensor
RCI (Rutherford Controls) 8310, 8320, 8371 Compact designs; popular for glass door and storefront applications
DynaLock 2011, 2013, 3000 Value-priced; good for budget-conscious multi-door installations
Schlage Electronics M490 Series Allegion brand; pairs with Schlage access control systems

All of these brands are available at wholesale pricing from BandHdepot.com. Contact our team for product availability, compatibility questions, and project pricing.

10. Frequently Asked Questions

Q: What is the difference between an electric strike and a magnetic lock?
A: An electric strike replaces the strike plate in the door frame and works with the existing mechanical lock — it releases the keeper to let the latch pass through. A magnetic lock (maglock) uses an electromagnet on the frame and an armature plate on the door to hold the door closed with magnetic force alone. The key differences are that electric strikes can be fail-secure (stay locked during power loss) and have a mechanical key override, while maglocks are always fail-safe (unlock on power loss) and have no key backup.
Q: Which is more secure — an electric strike or a maglock?
A: It depends on the application. An electric strike paired with a Grade 1 mortise lock provides higher mechanical holding force (1,200–1,500 lb) and retains a key override. A maglock provides 600–1,200 lb of holding force but has no key backup and releases on any power interruption. For fail-secure requirements where the door must stay locked during outages, an electric strike is the more secure choice.
Q: Can I use a maglock on a fire exit door?
A: Yes, but with additional hardware. A maglock on an egress door must include a request-to-exit (REX) sensor or push button on the egress side, an emergency release mechanism, and a fire alarm tie-in that automatically releases the magnet when the fire alarm activates. These requirements come from NFPA 101 and the IBC. Always verify specific requirements with your local Authority Having Jurisdiction (AHJ).
Q: What happens to each lock type during a power outage?
A: A magnetic lock releases immediately — it is always fail-safe, meaning the door unlocks when power is lost. An electric strike can be either: a fail-safe strike unlocks on power loss, while a fail-secure strike keeps the door locked. With a fail-secure strike, occupants can still exit using the mechanical lever handle on the egress side.
Q: Which is easier to install?
A: Magnetic locks are generally faster and easier to install. They surface-mount to the frame header with screws — no frame cutting or mortising required. Electric strikes require modifying the door frame to fit the strike body, which takes more time and skill, especially in steel frames. However, maglocks also need REX sensors, emergency release buttons, and fire alarm wiring, which adds to the total installation scope.
Q: Can I use a maglock on a glass door?
A: Yes — maglocks are one of the best options for glass doors and frameless glass storefronts. Because they surface-mount to the frame header and door top, they don’t require any modification to the glass. For narrow aluminum frames where an electric strike would not fit, a maglock is often the only practical choice.
Q: How much holding force do I need?
A: For most standard commercial interior doors, a 600 lb maglock is sufficient. Exterior doors, high-security areas, and doors exposed to wind load should have 1,200 lb maglocks or an electric strike with a Grade 1 lockset. Very high-security applications (evidence rooms, pharmaceutical storage) may require 1,500 lb units.
Q: Where can I buy commercial electric strikes and magnetic locks at wholesale prices?
A: BandHdepot.com carries a full selection of commercial electric strikes and magnetic locks from HES, Securitron, SDC, RCI, DynaLock, Schlage, and more. We offer wholesale pricing for locksmiths, contractors, facility managers, and government procurement (SAM-registered). Call (954) 734-2867 or email sales@bandhdepot.com for quotes.

Need Electric Strikes or Magnetic Locks? BandHdepot.com Has You Covered.

We stock commercial electric strikes and magnetic locks from HES, Securitron, SDC, RCI, DynaLock, Schlage, and more. All products ship from 26 US warehouse locations with wholesale pricing for contractors, locksmiths, architects, and facility managers.

Shop now: www.BandHdepot.com  |  Call: (954) 734-2867  |  Email: sales@bandhdepot.com

This electric strikes vs. magnetic locks buyer’s guide is published by BandHdepot.com, operated by B&H Depot LLC — a commercial door hardware and access control distributor established in 2006. We serve professional locksmiths, property managers, facility managers, and contractors nationwide with over 1 million products across 26 US warehouse locations. We are SAM-registered for government procurement. For expert assistance with electric lock selection and project specification, contact our team at sales@bandhdepot.com.